Electrical Insulating Rubber Mat (High Voltage Electromat) in Nairobi Kenya

Electrical Insulating Rubber Mat (High Voltage Electromat) in Nairobi Kenya

An Electromats or High Voltage Electrical Insulation Rubber Mat is a safety rubber mat designed in order to protect and guaranteed the safety of workers/users of high voltage areas from experiencing electrical shock which might lead to injury or death in case of electrical faults or power surge. Dandy Solutions offers electrical safety matting rated 450 volts working. It is the lowest voltage matting we offer that also complies with health and safety standards. At 6mm thick this matting offers a lightweight alternative to other electrical matting products. We regularly supply this product for use on assembly lines or applications which are using a 240 volt single phase switchgear. We always recommend allowing a 90% safety margin in order to protect against potential electrical discharge.

Description

An Electromats or High Voltage Electrical Insulation Rubber Mat is a safety rubber mat designed in order to protect and guaranteed the safety of workers/users of high voltage areas from experiencing electrical shock which might lead to injury or death in case of electrical faults or power surge. Dandy Solutions offers electrical safety matting rated 450 volts working. It is the lowest voltage matting we offer that also complies with health and safety standards. At 6mm thick this matting offers a lightweight alternative to other electrical matting products. We regularly supply this product for use on assembly lines or applications which are using a 240 volt single phase switchgear. We always recommend allowing a 90% safety margin in order to protect against potential electrical discharge.

Application areas of Electrical Insulating Rubber Mat (High Voltage Electromat)

  • Designed and highly recommended to protect operators working in high voltage environments like control panels from experiencing electrical shock in any event of electrical faults or power surge.
  • Designed and highly recommended for use in High Voltage Panels
  • Used in Sub-stations
  • Used in Power Transformer Rooms
  • Used in LT & HT Labs

HOW TO GET THE MOST OUT OF YOUR ELECTRICAL SAFETY MATTING Increasing the life expectancy of the matting

  • Storage Matting should be stored in a container or package. Care should be taken in order to ensure that the matting is not compressed, folded or stored in proximity to steam pipes, radiators or other sources of artificial heat or exposed to direct sunlight, artificial light or other sources of ozone. It is desirable that the ambient temperature be between 10°C and 21°C.
  • Transportation It is recommended that the matting be packaged in an individual container of sufficient strength to properly protect the matting from damage.
  • Examination Before Use Each time before use, the matting should be visually inspected. If the matting is thought to be unsafe, it should not be used and should be returned for testing or to be destroyed.
  • Precautions In Use Matting should not be exposed unnecessarily to heat, light or to be allowed to come into contact with oil, grease, turpentine, white spirit or strong acid.

When rubber matting becomes soiled, it should be washed with warm water, soap and then dried thoroughly. If insulating compounds such as paint continue to stick to the mat, the affected parts should be wiped immediately with a suitable solvent, avoiding excessive solvent use, and then immediately washed and treated as described above. Matting which becomes wet in use or by washing should be dried thoroughly, ensuring that the temperature of the matting does not exceed 65°C

Call +254748246998 to place your order

Swift delivery within Kenya. Huge price (KES) discounts on larg

Application areas of Electrical Insulating Rubber Mat (High Voltage Electromat)

  • Designed and highly recommended to protect operators working in high voltage environments like control panels from experiencing electrical shock in any event of electrical faults or power surge.
  • Designed and highly recommended for use in High Voltage Panels
  • Used in Sub-stations
  • Used in Power Transformer Rooms
  • Used in LT & HT Labs

How to get the most out of your electrical insulating rubber mat

Increasing the life expectancy of the matting

  • Storage Matting should be stored in a container or package. Care should be taken in order to ensure that the matting is not compressed, folded or stored in proximity to steam pipes, radiators or other sources of artificial heat or exposed to direct sunlight, artificial light or other sources of ozone. It is desirable that the ambient temperature be between 10°C and 21°C.
  • Transportation It is recommended that the matting be packaged in an individual container of sufficient strength to properly protect the matting from damage.
  • Examination Before Use Each time before use, the matting should be visually inspected. If the matting is thought to be unsafe, it should not be used and should be returned for testing or to be destroyed.
  • Precautions In Use Matting should not be exposed unnecessarily to heat, light or to be allowed to come into contact with oil, grease, turpentine, white spirit or strong acid.

When rubber matting becomes soiled, it should be washed with warm water, soap and then dried thoroughly. If insulating compounds such as paint continue to stick to the mat, the affected parts should be wiped immediately with a suitable solvent, avoiding excessive solvent use, and then immediately washed and treated as described above. Matting which becomes wet in use or by washing should be dried thoroughly, ensuring that the temperature of the matting does not exceed 65°C

Specifications

  • Dimensions: 10Mx1Mx4.8mm.
  • Surface Design: TOP FINE RIBBED & BOTTOM TEXTURED ASTM-D178 CLASS: 1 TYPE- I
  • Working Voltage: 7500volts
  • Maximum Withstand: 20,000volts